With our specially designed product pellet burner MPB, our expertise and long term experience, we can offer you a simple and reliable solution to upgrade your existing boiler installation with a pellet burner.
MPB is a pellet burner for wood pellet with diameter 6-8 mm. Thanks to the construction with a forward burning flame, this burner will give the most effective combustion and it is easy to fit it to the most boilers on the market.
The heat output of the burner can be set fixed, or can be set automatically according to the heat demand. The burner furnace is produced of fireproof stainless steel which is resistant to temperature up to 1.150°С.
The burner comes with its own controller, which can support multiple functions and standard feeding screw of 1,5m length. The burner comes in two versions: manual cleaning and automatic cleaning by means of compressed air.
ADVANTAGES OF UPGRADING YOUR BOILER WITH A PELLET BURNER
Economy and Convenience
Our devices are compatible with any kind of wood pellet! Thanks to the automatic cleaning system with compressed air, the burner can be used with economy quality wood pellet (class: A1, A2 and B). The burner is cleaned automatically at pre-set time intervals.
Comfort
Our burner will automatically set the power level according to the heat demand, start and stop automatically from a room thermostat, and control the domestic hot water tank.
Low emissions
The burner has minimum emission (CO, NOx, OGC) and dust to the atmosphere, reaching the lowest limits according to the European requirements. This way, we protect the environment, and assure sustainability.
Adaptability
The MPB burner can be installed on an existing boiler, either cast iron or steel, even on a gasification boiler. For mounting the burner on a Viadrus boiler, a full kit is offered which includes: modified door, mounting flange, cast iron elements for efficiency increase.
The following table gives general requirements for installing the burner on an existing boiler. The fire chamber dimensions refer to natural draught boilers (the dimensions can differ with a margin of 10% from the mentioned values). If the L dimension is smaller, the H dimension must be bigger to obtain the necessary power.
If the mounting of the burner will be on a pressurized flame boiler (return flame), please contact the producer.
| Minimum combustion chamber dimensions | Flame tube diameter | Door flange diameter | ||||
| Burner type | Recommended burner power | L | W | H | D | D1 |
| kW | mm | mm | mm | |||
| NANI 35 | 20 | 350 | 300 | 350 | 145 | 153 |
| NANI 35/MPB 60 | 35 | 450 | 350 | 400 | 145 | 153 |
| MPB 60 | 50 | 600 | 400 | 500 | 180 | 186 |
| MPB 80 | 65 | 650 | 400 | 500 | 180 | 186 |
| MPB 80 | 80 | 700 | 500 | 500 | 180 | 186 |
| MPB 150 PRO | 100 | 900 | 600 | 600 | 204 | 210 |
| MPB 150 PRO | 120 | 1.000 | 600 | 600 | 204 | 210 |
| MPB 150 PRO | 150 | 1.100 | 600 | 700 | 204 | 210 |
| MPB 250 PRO | 200 | 1.200 | 700 | 700 | 254 | 260 |
| MPB 250 PRO | 250 | 1.300 | 800 | 800 | 254 | 260 |