MAIN FEATURES
Big fire chamber for high volume of fuel loading
Three pass construction for high efficiency and small dimensions
Robust construction
Tubed heat exchanger
Easy installation of a pellet burner
Removable safety heat exchanger (optional)
Digital controller with user-friendly interface
Control of heating pump and hot water pump
Full fan modulation
Exhaust gas temperature sensor (optional)
Automatic fuel lack recognition
Ingition mode and flame supervision mode
Overheating alarm signal
TECHNICAL DATA
T1 - Outlet
T2 - Return
T3 - Chimney
T4 - Drainage
T5 - Safety heat exchanger
Type | ECWP 25 | ECWP 30 | ECWP 40 | ECWP 50 | ECWP 60 | ECWP 80 | ECWP 100 | ||
Nominal power | kW | 25 | 30 | 40 | 50 | 60 | 80 | 100 | |
Efficiency | % | 83 | 83 | 83 | 83 | 83 | 83 | 83 | |
Temperature max | ℃ | 90 | 90 | 90 | 90 | 90 | 90 | 90 | |
Pressure max | bar | 3 | 3 | 3 | 3 | 3 | 3 | 3 | |
Water contents | lit | 100 | 120 | 130 | 170 | 190 | 370 | 440 | |
Weight | kg | 259 | 282 | 307 | 355 | 385 | 675 | 765 | |
Electric supply | V/Hz | 230/50 | 230/50 | 230/50 | 230/50 | 230/50 | 230/50 | 230/50 | |
Dimensions | H1 | mm | 1280 | 1280 | 1280 | 1395 | 1395 | 1740 | 1740 |
W | mm | 530 | 530 | 530 | 660 | 660 | 785 | 785 | |
F | mm | 880 | 880 | 880 | 1000 | 1000 | 1195 | 1195 | |
L1 | mm | 1085 | 1185 | 1285 | 1185 | 1285 | 1540 | 1740 | |
T1-T2 | inch | 1 ½” | 1 ½” | 1 ½” | 1 ½” | 1 ½” | 2" | 2" | |
T3 | mm | Ø180 | Ø180 | Ø180 | Ø180 | Ø180 | Ø200 | Ø200 | |
T4 | inch | ¾” | ¾” | ¾” | ¾” | ¾” | ¾” | ¾” | |
T5 | inch | 2" | 2" | 2" | 2" | 2" | 2 ½” | 2 ½” |
POWER CALCULATOR
CONTACT OUR SPECIALIST
ACCESSORIES